0 5 ton water tube steam boiler

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :0 5 ton water tube steam boiler
  • Supply Capacity : 10 units/month :0 5 ton water tube steam boiler
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

Get display discount

Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • Sterlco | Sterling Steam Control Part Numbers

    M&M Control distributes the finest names in the industry such as Sterlco Sterling Steam Control. Products include Steam Traps, Y Strainers, Temperature Control Valves, Hand Radiator Valves, Temperature Control Units, Boiler Feed Pumps, NPSH K Pump, Condensate Pumps, Centrifugal Pumps and More.Get Price

  • Power plant and calculations: Boiler calculations for

    Feb 12, 2021 · 10-Calculate the Sulphur dioxide generated per day in a 150 TPH boiler, where coal burned is having 0.5% of sulphur. Consider steam to fuel ratio 5.5 & Boiler operates on full load for 24 hours. We have S + O2 = SO2. 32 + 32 = 64. 1 + 1 = 2. That is 1 kg of sulphur generates 2 kg of Sulphur dioxide on complete combustion.Get Price

  • Waste Heat Recovery Methods And Technologies - Chemical

    Jan 01, 2013 · An economizer or APH for water-tube boilers is typically not attractive for units operating under 10 kg/cm 2 g or below 20 ton/h of steam production, nor any size boiler that will normally run at reduced capacity. For industrial boilers, dual installation using both an economizer and an APH is rarely economical or installed.Get Price

  • Steam Generators and Fluid Heaters Clayton Industries

    Industrial Steam Boilers (Coil Tube Boilers) Clayton is an industrial steam boiler manufacturer of fired steam generators and fluid heater steam generators. Clayton's industrial process steam boilers are available in 18 sizes from 15 to 2000 Boiler Horsepower (150 to 20,000 kW) and 518 to 69,000 pounds of steam per hour (235 to 37,300 kg/hr).Get Price

  • (PPT) PIPE 1 COACHING NOTES 150 | pauline agustin

    From steam tables: At 70 bar (7Mpa) and 65oC: v1 = 0.001017 m3/kg At 50 bar (5Mpa) and 700oK(427oC): v2 = 0.06081 m3/kg A. 1.56 B. 2.51 C. 1.672 D. 3.230 59. Water substance at 70 bar and 65oC enters a boiler tube of constant inside diameter of 35mm. The water leaves the boiler tube at 50 bar and 700oK at velocity of 150 m/s.Get Price

  • Tomato Processing Plant - Sauce, Ketchup, Paste - Tomato

    It is made up of tube in tube spira flow pipes for steam and products Steam Boiler with Water softener, Cooling Tower, pump piping, Air compressor, Approx. Rs 100 Lakh / Unit Get Latest Price. Product Details: Capacity: 0.5 M Ton/Hr. To 10 M Ton/Hr. Input Capacity: 0.5 M Ton/Hr. To 10 M Ton/Hr. Automation Grade: AutomaticGet Price

  • Waste Heat Recovery Methods And Technologies - Chemical

    Jan 01, 2013 · An economizer or APH for water-tube boilers is typically not attractive for units operating under 10 kg/cm 2 g or below 20 ton/h of steam production, nor any size boiler that will normally run at reduced capacity. For industrial boilers, dual installation using both an economizer and an APH is rarely economical or installed.Get Price

  • Steam Generators and Fluid Heaters Clayton Industries

    Industrial Steam Boilers (Coil Tube Boilers) Clayton is an industrial steam boiler manufacturer of fired steam generators and fluid heater steam generators. Clayton's industrial process steam boilers are available in 18 sizes from 15 to 2000 Boiler Horsepower (150 to 20,000 kW) and 518 to 69,000 pounds of steam per hour (235 to 37,300 kg/hr).Get Price

  • Energy Glossary

    BOILER - A closed vessel in which water is converted to pressurized steam. BOILING WATER REACTOR - (BWR) A nuclear power unit in which water used as a coolant is allowed to boil at the core. The resulting steam may be used to drive electric turbines.Get Price

  • PB TYPE MARINE BOILER

    MARINE BOILER Steam Capacity Working pressure Dry weight (ton/hr) (kg/cm2) DH(ton) MS01 0.5 7.0 1,142 1,900 2.2 MS02 1.0 7.0 1,405 2,305 3.5 Note. 1. Dimension : Boiler body (Excluding insulation) 2. Dry weight : Boiler body (Excluding water) 3. Working pressure : Accroding to requirement Dimension table Type Dimmension (mm)Get Price

  • (PPT) PIPE 1 COACHING NOTES 150 | pauline agustin

    From steam tables: At 70 bar (7Mpa) and 65oC: v1 = 0.001017 m3/kg At 50 bar (5Mpa) and 700oK(427oC): v2 = 0.06081 m3/kg A. 1.56 B. 2.51 C. 1.672 D. 3.230 59. Water substance at 70 bar and 65oC enters a boiler tube of constant inside diameter of 35mm. The water leaves the boiler tube at 50 bar and 700oK at velocity of 150 m/s.Get Price

  • Tomato Processing Plant - Sauce, Ketchup, Paste - Tomato

    It is made up of tube in tube spira flow pipes for steam and products Steam Boiler with Water softener, Cooling Tower, pump piping, Air compressor, Approx. Rs 100 Lakh / Unit Get Latest Price. Product Details: Capacity: 0.5 M Ton/Hr. To 10 M Ton/Hr. Input Capacity: 0.5 M Ton/Hr. To 10 M Ton/Hr. Automation Grade: AutomaticGet Price

  • Sterlco | Sterling Steam Control Part Numbers

    M&M Control distributes the finest names in the industry such as Sterlco Sterling Steam Control. Products include Steam Traps, Y Strainers, Temperature Control Valves, Hand Radiator Valves, Temperature Control Units, Boiler Feed Pumps, NPSH K Pump, Condensate Pumps, Centrifugal Pumps and More.Get Price

  • PB TYPE MARINE BOILER

    MARINE BOILER Steam Capacity Working pressure Dry weight (ton/hr) (kg/cm2) DH(ton) MS01 0.5 7.0 1,142 1,900 2.2 MS02 1.0 7.0 1,405 2,305 3.5 Note. 1. Dimension : Boiler body (Excluding insulation) 2. Dry weight : Boiler body (Excluding water) 3. Working pressure : Accroding to requirement Dimension table Type Dimmension (mm)Get Price

  • Engine Thermal Efficiency - an overview | ScienceDirect Topics

    By assuming that heat loss from this flash boiler system is 5% of the heat rejected from the engine and that steam and condensate are at the same temperature, the flash boiler output was estimated to be about 907 kg (2000 pounds) per hour of saturated steam at 63.3°C (146 F).Get Price

  • Power plant and calculations: Boiler calculations for

    Feb 12, 2021 · 10-Calculate the Sulphur dioxide generated per day in a 150 TPH boiler, where coal burned is having 0.5% of sulphur. Consider steam to fuel ratio 5.5 & Boiler operates on full load for 24 hours. We have S + O2 = SO2. 32 + 32 = 64. 1 + 1 = 2. That is 1 kg of sulphur generates 2 kg of Sulphur dioxide on complete combustion.Get Price

  • Engine Thermal Efficiency - an overview | ScienceDirect Topics

    By assuming that heat loss from this flash boiler system is 5% of the heat rejected from the engine and that steam and condensate are at the same temperature, the flash boiler output was estimated to be about 907 kg (2000 pounds) per hour of saturated steam at 63.3°C (146 F).Get Price